KVBbShvng, KVBbShvng-LS, AKVBbShvng, AKVBbShvng-LS (ngd)

1128 Available
5.34$
13868 Available
8.93$
18450 Available
6.26$
10224 Available
4.39$
1349 Available
2.95$
10147 Available
2.38$
20275 Available
4.66$
7237 Available
3.31$
25432 Available
10.65$
7530 Available
2.34$
17807 Available
5.47$
19367 Available
3.82$
15215 Available
3.15$
17791 Available
2.20$
9316 Available
1.83$
22129 Available
4.28$

CABLES KVBbShvng, KVBbShvng-LS (ngd), AKVBbShvng, AKVBbShvng-LS (ngd)
TU U 27.3-33527835-003:2015

Control cables with copper or aluminum conductors, PVC insulation, and sheath with protective covering.
The abbreviation KVBbShvng, KVBbShvng-LS (ngd), AKVBbShvng, AKVBbShvng-LS (ngd) is deciphered as follows:

CONSTRUCTION

  1. Current-carrying conductor – single-wire, copper or aluminum, Class 1 according to DSTU EN 60228.
  2. Insulation – made of polyvinyl chloride (PVC) plastic, in cables with the index "ng-LS (ngd)" – made of fire-retardant PVC plastic.
  3. Twisting – insulated conductors twisted together. Each layer of the cable contains a reference pair, the conductors of which differ in insulation color from the other conductors in the layer.
  4. Separation layer – applied over the twisted conductors, made of fire-retardant PVC plastic, with a thickness of at least 0.5 mm, in cables with the index "ng-LS (ngd)" – made of fire-retardant PVC plastic.
  5. Protective covering type BBShv:
    • armor made of two galvanized steel strips, applied with overlap in a spiral so that the upper strip covers the gaps between the turns of the lower strip;
    • protective hose – made of fire-retardant PVC plastic, in cables with the index "ng-LS (ngd)" – made of fire-retardant PVC plastic.

TECHNICAL CHARACTERISTICS

Operating temperature of the environment from -50°C to +50°C.
Relative air humidity at +35°C – 98%.
Electrical insulation resistance at +20°C with a cross-section of:

Long-term allowable temperature of the current-carrying conductors during operation is +70°C.
The cables are resistant to installation bends.
The bending radius of armored cables during installation and laying without preheating at ambient temperatures no lower than -7°C is not less than 10 cable diameters.
Cable construction length – at least 150 meters.
Warranty period of operation – 3 years from the date of commissioning.
Cable service life – at least 15 years.
Service life when laid in rooms, channels, tunnels – at least 25 years.

APPLICATION

Control cables are designed for connecting stationary electrical devices, equipment, and electrical distribution units at AC voltages up to 660 V with a frequency of up to 100 Hz or DC voltages up to 1000 V.
For single and bundled laying in rooms, channels, tunnels, trays, ducts, pipes, flexible conduits without significant tensile loads, as well as in the ground (trenches) with low corrosive activity, in places where stray currents are possible.
Cables of the KVBbShvng-LS (ngd), AKVBbShvng-LS (ngd) brands are designed for installation in areas where low emission of smoke, toxic, and corrosive gases is required during combustion and smoldering.

Outer diameter and calculated weight of 1 km of cable

Number and nominal
cross-section of conductors, mm²
KVBbShvng AKVBbShvng KVBbShvng-LS AKVBbShvng-LS
Diameter
mm
Weight
kg
Diameter
mm
Weight
kg
Diameter
mm
Weight
kg
Diameter
mm
Weight
kg
4х0,7513,3241--13,3243--
5х0,7513,9266--13,9268--
7х0,7514,6302--14,6306--
10х0,7516,8384--16,8389--
14х0,7518,1464--18,1471--
19х0,7519,3549--19,3558--
27х0,7521,8694--21,8707--
37х0,7524,1868--24,1886--
4х1,011,6252--11,6259--
5х1,012,3281--12,3289--
7х1,013,0324--13,0333--
10х1,015,3419--15,3431--
14х1,016,3495--16,3510--
19х1,018,1612--18,1631--
27х1,020,7785--20,7810--
37х1,023,1991--23,11024--
4х1,512,2286--12,2294--
5х1,513,0322--13,0331--
7х1,513,7377--13,7387--
10х1,516,3493--16,3506--
14х1,517,8609--17,8627--
19х1,519,3739--19,3761--
27х1,522,7982--22,71012--
37х1,524,91224--24,91261--
4х2,513,234813,228513,235713,2294
5х2,514,039714,031714,040714,0328
7х2,514,947514,936414,948714,9377
10х2,518,364818,348918,366418,3508
14х2,519,579219,557119,581219,5593
19х2,521,397821,367821,3100221,3705
27х2,525,1131425,188925,1134825,1926
37х2,527,7166427,7108227,7170727,71128
4х4,014,844814,834814,845914,8360
7х4,017,364917,347317,366517,34491
10х4,021,087021,062021,089121,0643
4х6,016,055716,040616,057016,0419
7х6,018,982618,956118,984518,9581
10х6,023,4114323,476423,4116923,4793
4х10--19,3561--19,3581
7х10--22,9792--22,9822
10х10--28,21059--28,21099

Why buy KVBbShvng, KVBbShvng-LS (ngd), AKVBbShvng, AKVBbShvng-LS (ngd) cable from "Energoalliance"

It is more profitable to purchase cable products wholesale or retail directly from the manufacturer. "Energoalliance" is one of the industry leaders. The company has been known on the market since 2005 and offers certified products at affordable prices. The assortment includes power, installation, and control cables. We cooperate with electrical installation companies, utilities, factories, and private individuals. The company works with customers from Ukraine, CIS, and Europe, offering comfortable individual terms of cooperation. The delivery price depends on the current postal service rates.


Categories