PTGV CABLE
TU U 27.3-33527835-022:2021

Flexible thermoelectrode wire with PVC insulation.
The abbreviation PTGV stands for:

STRUCTURE

  1. Conductive core, single-wire, with a nominal cross-section from 0.20 to 2.50 mm² inclusive:
    • PTGV-M – copper-constantan;
    • PTGV-P – copper-copper-nickel alloy TP;
    • PTGV-MK – copper-copel;
    • PTGV-HK – chromel-copel;
    • PTGV-HA – chromel-alumel;
    • PTGV-M-MN – copper-copper-nickel alloy MN.
  2. Insulation made of PVC compound, with separation between cores. Insulated cores have coloring and are marked with a stripe.

  3. Pair
    Designation
    Insulation Color Metal or Alloy
    Indicated by Stripe
    MBrownCopper
    PGreenCopper
    HKPurple
    or Black
    Chromel
    MKYellow
    or Orange
    Copper

    Wire
    Brand
    Number
    of Cores
    Nominal Core Cross-Section, mm²
    Copper Alloys
    Constantan,
    Chromel, Copel
    MN 2.15 TP
    PTGV20.200.200.20
    0.751.001.00-
    0.751.501.50-
    1.002.502.50-
    1.00--1.00
    1.50--1.50
    2.50--2.50

TECHNICAL CHARACTERISTICS

Operating ambient temperature: -40 to +70 °C.
Relative air humidity at +35 °C – 98%.
Wire installation can be performed at an ambient temperature not lower than -15 °C.
Electrical resistance of the insulation per 1 m length at 20 °C: not less than 1000 MΩ.
Insulation resistance at relative air humidity up to 98% and temperature (35 ± 3) °C after 48 hours of exposure, recalculated to 1 m length: not less than 100 MΩ.
Test AC voltage at 50 Hz: 1500 V for 5 minutes.
Construction length of the cable: at least 100 meters.
Warranty period of operation: 2 years from the date of putting the wires into operation.

APPLICATION

The wires are designed for connection to temperature measurement devices. Suitable for laying indoors, in pipes, as well as inside devices, under operating temperatures from -40 to +70 °C.

Calculated diameter and weight of 1 km of wire

Wire
type
Number of
conductors
Nominal cross-section of conductors, mm² Maximum outer
diameter of wire, mm
Calculated
wire weight,
kg/km
Copper Alloys
Constantan,
Chromel, Copel
MN-2.15 TP Pair material designations
M, MK, M-MN P, HK
PTGV20.751.001.002.6 x 6.22.8 x 6.227.7-
0.751.501.502.6 x 6.02.7 x 6.333.3-
1.002.502.502.8 x 6.23.4 x 6.646.3-
1.001.003.2 x 6.5-30.8
1.501.50-41.9
2.50--2.50-65.3

Why you should buy PTGV cable from the company “Energoalliance”

It is more beneficial to purchase cable products in bulk or retail directly from the manufacturer. “Energoalliance” is one of the leaders in the industry. The company has been on the market since 2005 and offers certified products at affordable prices. The range includes power, installation, and control cables. We cooperate with electrical installation companies, utility enterprises, factories, and individuals. The company works with clients from Ukraine, CIS countries, and Europe, offering convenient individual cooperation terms. Delivery costs depend on the current postal service rates.