Wire NV, NVE, NVM, NVME
TU U 27.3-33527835-040:2023

NV - mounting wire with a tinned copper conductor, with polyvinyl chloride insulation;
NVE - mounting wire with a tinned copper conductor, with polyvinyl chloride insulation, shielded;
NVM - mounting wire with a copper conductor, with polyvinyl chloride insulation;
NVME - mounting wire with a copper conductor, with polyvinyl chloride insulation, shielded.

CONSTRUCTION

  1. Nominal cross-section, number of conductors, and nominal AC voltage:

  2. Wire Type Number of Conductors Nominal Cross-Section, mm² Nominal AC Voltage, V
    NV, NVM10.20; 0.35; 0.50; 0.75; 1.00; 1.5; 2.5600 and 1000
    NVE1, 2, 30.20; 0.35; 0.50; 0.75; 1.00; 1.5; 2.5600 and 1000
    NVME1, 2, 30.20; 0.35; 0.5; 0.75; 1.0600
    10.20; 0.35; 0.50; 0.75; 1.00; 1.5; 2.51000
    2, 30.20; 0.35; 0.5; 0.75; 1.0

  3. Polyvinyl chloride insulation.
  4. Insulated conductors in shielded wires are twisted together.
  5. Shield of tinned copper wires for NVE and copper wires for NVME.
    Wire diameter – no more than 0.15 mm, with a shield density factor of at least 70%.

TECHNICAL SPECIFICATIONS

Operating ambient temperature from -40 °C to +70 °C.
Relative humidity at +35°C – 98%.
Electrical insulation resistance for 1 km length at 20 °C, not less than 10 MOhm.
Shielded wires for 600 V and 1000 V must withstand 2000 V and 3000 V AC for 1 minute at 50 Hz with prior soaking in water for 30 minutes; unshielded ones – AC only.
Minimum bending radius during installation – 5 wire diameters.
Minimum length for unshielded wires should be 50 m, and for shielded wires – at least 20 m.
Warranty period – 1.5 years from the date of commissioning.

APPLICATION

Wires are designed to operate at a nominal AC voltage of 600 and 1000 V with frequencies up to 10,000 Hz and DC voltage of 840 and 1400 V in general industrial electrical circuits.

Maximum Wire Diameter

Conductor Cross-Section, mm² Maximum Outer Diameter of Wires, mm
Voltage 600 V, Types Voltage 1000 V, Types
NV,
NVM
NVE NVME NV,
NVM
NVE,
NVME
NVE NVME
1 1 2 3 1 2 3 1 1 2 3 2 3
Number of Conductors
0,201,523,63,823,63,81,72,244,344,3
0,351,62,23,84,12,23,84,11,82,44,24,54,24,5
0,501,82,34,24,52,34,24,522,54,64,94,64,9
0,752,12,74,85,12,74,85,12,32,95,25,65,25,6
1,002,22,855,32,855,32,435,45,85,45,8
1,502,53,15,66---2,73,366,4--
2,503,23,877,5---3,33,97,27,7--

Why Buy NV, NVE, NVM, NVME Cable from Energoalliance

Purchasing cable products in large or small wholesale quantities is more advantageous directly from the manufacturer. Energoalliance is one of the industry leaders. Established in 2005, the company is known for offering certified products at affordable prices. The range includes power, installation, and control cables. We work with electrical installation companies, utility enterprises, factories, and private individuals. Energoalliance partners with clients from Ukraine, the CIS, and Europe, providing comfortable, tailored cooperation terms. Delivery costs depend on the current postal service rates.